Structural Protection
Steel Structure
Steel Structure
48 number of results
48 results for
Name
Fire resistance
FRL 60/-/-  Coating to steel beam with Cafco MANDOLITE®-CP2
FRL 60/-/- Coating to steel beam with Cafco MANDOLITE®-CP2
FRL 60/-/- Coating to steel beam with Cafco MANDOLITE®-CP2
60 min
FRL 60/-/-  Coating to steel column with Cafco MANDOLITE®-CP2
FRL 60/-/- Coating to steel column with Cafco MANDOLITE®-CP2
FRL 60/-/- Coating to steel column with Cafco MANDOLITE®-CP2
60 min
FRL 90/-/-  Coating to steel beam with Cafco MANDOLITE®-CP2
FRL 90/-/- Coating to steel beam with Cafco MANDOLITE®-CP2
FRL 90/-/- Coating to steel beam with Cafco MANDOLITE®-CP2
90 min
FRL 90/-/-  Coating to steel column with Cafco MANDOLITE®-CP2
FRL 90/-/- Coating to steel column with Cafco MANDOLITE®-CP2
FRL 90/-/- Coating to steel column with Cafco MANDOLITE®-CP2
90 min
FRL 120/-/-  Coating to steel beam with Cafco MANDOLITE®-CP2
FRL 120/-/- Coating to steel beam with Cafco MANDOLITE®-CP2
FRL 120/-/- Coating to steel beam with Cafco MANDOLITE®-CP2
120 min
FRL 120/-/-  Coating to steel column with Cafco MANDOLITE®-CP2
FRL 120/-/- Coating to steel column with Cafco MANDOLITE®-CP2
FRL 120/-/- Coating to steel column with Cafco MANDOLITE®-CP2
120 min
FRL 60/-/-  Coating to steel beam with CAFCO® 300
FRL 60/-/- Coating to steel beam with CAFCO® 300
FRL 60/-/- Coating to steel beam with CAFCO® 300
60 min
FRL 60/-/-  Coating to steel column with CAFCO® 300
FRL 60/-/- Coating to steel column with CAFCO® 300
FRL 60/-/- Coating to steel column with CAFCO® 300
60 min
FRL 90/-/-  Coating to steel beam with CAFCO® 300
FRL 90/-/- Coating to steel beam with CAFCO® 300
FRL 90/-/- Coating to steel beam with CAFCO® 300
90 min
FRL 90/-/-  Coating to steel column with CAFCO® 300
FRL 90/-/- Coating to steel column with CAFCO® 300
FRL 90/-/- Coating to steel column with CAFCO® 300
90 min
Items per page
Page 1 of 5

Structural Protection

Steel loses its loadbearing capacity at a temperature in excess of 550°C during a fire; therefore structural steel protection (e.g. with board, paint, spray etc) is required to preserve the stability of the building structure in the event of fire. All Promat products and systems have been tested at nationally accredited laboratories around the world to a variety of standards, e.g. BS 476: Part 21, AS 1530: Part 4, AS4100,  DIN 4102, ASTM E119 and EN 13381-4.

Promat offers highly effective solutions for fire stability in load-bearing building structures, including beams and columns.
"All In One" solution with direct attachment of PROMATECT® 250 or PROMATECT®-XS encasement.
"Quick" solution with direct spraying of the CAFCO® 300, Cafco FENDOLITE®-MII, or Cafco MANDOLITE®-CP2 spray coatings.
"Aesthetic" solution with an intumescent water-based paints Cafco SPRAYFILM® WB3, you opt for a perfect balance between performance and aesthetics.

Promat Technical Support

Contact our technical support team with your questions on passive fire protection solutions, our products and systems or installation advice...

Technical Documentation

Find the product datasheets, system brochures, Declarations of Performance, installation manuals and other documents you need to get the job done.